Title: | The Application of Fluorescence Microscopy and Scanning Electron Microscopy in the Detection of Delayed Ettringite Formation in Concrete |
Authors: | Matos, L. Silva, A.S. Soares, D. Salta, M. Mirao, J. Candeias, A. |
Keywords: | Delayed ettringite formation (DEF) Scanning electron microscopy (SEM) Petrographic examination Fluorescence microscopy Concrete |
Issue Date: | 2010 |
Publisher: | Trans Tech Publications |
Citation: | L. Matos, A.S. Silva, D. Soares, M. Salta, J. Mirão, A. Candeias (2010) "The application of fluorescence microscopy and scanning electron microscopy in the detection of delayed ettringite formation in concrete", Mater. Sci. For., 636-637, 1266-1271. |
Abstract: | The degradation of concrete structures caused by delayed ettringite formation (DEF) is a problem that nowadays affects many concrete structures worldwide. This pathology is due to the formation of an expansive compound – ettringite - inside the material. This is a hydrated calcium sulphoaluminate produced by the chemical reaction between sulphate ions, calcium hydroxide and alumina present in the Portland cement paste. This product, normally formed during the hydration
of cement, presents an acicular morphology (needles) that can be observed by scanning electron microscopy (SEM). However, DEF can also be formed after the setting of the cement causing, in this case, a deleterious expansion of the concrete. This secondary ettringite can also be produced after an excessive heating of the concrete, caused by a high amount of cement or by the use of heat
cure. SEM has been used to distinguish between expansive and non expansive ettringite based normally in morphology analysis, since the former is characterized by a compressed or compact nature where the needle shapes disappear or are welded together. Furthermore, the use of other
techniques, like X-ray diffraction or micro-XRF, has been limited because the compressed or compact ettringite is badly crystallized or even amorphous and the elemental composition is similar and therefore it is difficult to detect. This article presents a methodology for the diagnosis of DEF using polished concrete thin sections and combining polarised and fluorescence light optical microscopy with SEM-EDS. |