Please use this identifier to cite or link to this item: http://hdl.handle.net/10174/6056

Title: Analysis of loop heat pipe performance under varying wick load.
Authors: Reis, A. H.
Miguel, A. F.
Aydin, M.
Keywords: loop heat pipe performance
enhance cooling
Issue Date: 2004
Publisher: ASME - ZSIS
Citation: A. H. Reis, A. F. Miguel, M. Aydin (2004) Analysis of loop heat pipe performance under varying wick load. Proceedings of the ASME - ZSIS International Thermal Science Seminar II (editor: Bergles A. E.), Bled, Slovenia, 705-710
Abstract: Loop heat pipes (LHP) are heat transfer devices used to enhance cooling of small spaces and basically consist of sealed tubes connecting a heat source, the evaporator, whose major part is a porous wick, with a condenser that operates as heat sink. In this paper we analyse the effect of curvature of the liquid vapor interface upon the vapor pressure within wick pores.
URI: http://hdl.handle.net/10174/6056
ISBN: 9619139305
Type: article
Appears in Collections:FIS - Artigos em Livros de Actas/Proceedings
CGE - Artigos em Livros de Actas/Proceedings

Files in This Item:

File Description SizeFormat
ASME-ZSIS_Some Features of Flow and Particle Transport in Porous Structures.pdf610.22 kBAdobe PDFView/OpenRestrict Access. You can Request a copy!
FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpaceOrkut
Formato BibTex mendeley Endnote Logotipo do DeGóis 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 