Please use this identifier to cite or link to this item:
http://hdl.handle.net/10174/6056
|
Title: | Analysis of loop heat pipe performance under varying wick load. |
Authors: | Reis, A. H. Miguel, A. F. Aydin, M. |
Keywords: | loop heat pipe performance enhance cooling |
Issue Date: | 2004 |
Publisher: | ASME - ZSIS |
Citation: | A. H. Reis, A. F. Miguel, M. Aydin (2004) Analysis of loop heat pipe performance under varying wick load. Proceedings of the ASME - ZSIS International Thermal Science Seminar II (editor: Bergles A. E.), Bled, Slovenia, 705-710 |
Abstract: | Loop heat pipes (LHP) are heat transfer devices used to enhance cooling of small spaces and basically consist of sealed
tubes connecting a heat source, the evaporator, whose major part is a porous wick, with a condenser that operates as
heat sink. In this paper we analyse the effect of curvature of the liquid vapor interface upon the vapor pressure within
wick pores. |
URI: | http://hdl.handle.net/10174/6056 |
ISBN: | 9619139305 |
Type: | article |
Appears in Collections: | FIS - Artigos em Livros de Actas/Proceedings CGE - Artigos em Livros de Actas/Proceedings
|