Please use this identifier to cite or link to this item: http://hdl.handle.net/10174/15976

Title: A problemática da refrigeração de sémen equino
Authors: Damásio, Liliane Isabel Costa
Advisors: Bettencourt, Elisa Maria Varela
Rocha, António Luíz Mittermayer Madureira Rodrigues da
Keywords: Garanhão
Androcoll-E®
SLC
Refrigeração
Sémen
Stallion
Androcoll-E®
SLC
Cooling
Sperm
Issue Date: 2013
Publisher: Universidade de Évora
Abstract: Um número significativo de garanhões produzem ejaculados de baixa qualidade e alta sensibilidade à refrigeração, necessitando de técnicas de processamento especializadas para otimizar a qualidade do sémen. Recentemente, foi disponibilizada uma técnica de centrifugação com monocamada (SLC) de Androcoll-E®, que tem demonstrado selecionar os espermatozoides (SPZ) de boa qualidade. No presente estudo pretendeu-se avaliar o efeito do tratamento com SLC na qualidade do sémen refrigerado, durante 72 horas. As amostras tratadas mostraram valores numéricos superiores para os parâmetros de motilidade, mas apenas se obtiveram valores estatisticamente significativos (p<0,05) para a velocidade curvilínea (VCL) e retilínea (VSL), medidas com um sistema computorizado de análise de sémen, nas amostras tratadas. O reduzido número de amostras e a elevada variabilidade das características seminais entre ejaculados, podem ser responsáveis pela ausência de diferenças estatisticamente significativas, pelo que seria de interesse alargar este estudo a um maior número de garanhões para consolidar as conclusões; ABSTRACT: A significant number of stallions produce ejaculates of low quality and high sensitivity to cooling, requiring specialized processing techniques to optimize the quality of sperm. Recently, a new protocol has been developed - the single layer centrifugation (SLC) with Androcoll-E®, which in some studies has been able to select good quality spermatozoa (SPZ). The objective of this study was to investigate the effect of SLC treatment on the quality of semen refrigerated for 72h. In our study, numerical improvements of motility parameters were seen in the treated samples, but only the curvilinear (VCL) and linear velocities (VSL) measured by a computer analysis system were significantly (p<0.05) higher in the treated samples. Lack of significance may have been due to the small sample size and high variability among ejaculates. Expanding this data set with the use of further ejaculates from different stallions is warranted to draw more definitive conclusions.
URI: http://hdl.handle.net/10174/15976
Type: masterThesis
Appears in Collections:BIB - Formação Avançada - Teses de Mestrado

Files in This Item:

File Description SizeFormat
Dissertação - Liliane Damásio.pdf2.66 MBAdobe PDFView/Open
FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpaceOrkut
Formato BibTex mendeley Endnote Logotipo do DeGóis 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Dspace Dspace
DSpace Software, version 1.6.2 Copyright © 2002-2008 MIT and Hewlett-Packard - Feedback
UEvora B-On Curriculum DeGois