Please use this identifier to cite or link to this item:
http://hdl.handle.net/10174/9055
|
Title: | Qualidade do ar interior e influência na conservação de objetos de prata- as salas de ourivesaria do Museu Nacional de Arte |
Authors: | Dias, Luis Carlos Rosmaninho |
Advisors: | Dias, Cristina Maria Barrocas Maduro, Belmira Maria Coroado Libânio da Silva |
Keywords: | compostos orgãnicos voláteis poluentes inorgânicos |
Issue Date: | 2013 |
Publisher: | Universidade de Évora |
Abstract: | Foi efetuada a monitorização do teor em compostos orgânicos voláteis (COVs), NO2, O3,
NH3 e H2S no ar interior das salas de ourivesaria e vitrinas do Museu Nacional de Arte
Antiga (MNAA). Os teores medidos revelaram que a qualidade do ar das salas e das
vitrinas abertas é influenciada pela entrada de ar do exterior do museu, apresentando
teores semelhantes aqueles registados noutros museus na Europa, ainda que dentro dos
valores mais elevados. A qualidade do ar da vitrina estanque é substancialmente diferente,
apresentando teores em COVs mais elevados e concentrações de poluentes inorgânicos
maioritariamente abaixo dos limites de quantificação.
A análise da camada de corrosão da prata revelou ser maioritariamente composta por
cloreto de prata (AgCl). Não foi possível estabelecer uma relação directa entre a natureza
da camada de corrosão e os poluentes monitorizados, já que o AgCl deverá ter origem na
presença de aerossóis marinhos no ar interior do MNAA.;Abstract
The contents in volatile organic compounds (VOCs) and inorganic pollutants, NO2, O3, NH3
and H2S, were measured inside the rooms and jewellery showcases the National Museum
of Ancient Art (NMAA). The levels measured showed that air quality of the rooms and
open showcases is strongly influenced by the influx of outside air. The pollutants
concentrations are similar to those measured in other European museums, although
within the highest range. The quality of the air-tight glass showcase analyzed is completely
different, with higher values in VOCs, and inorganic pollutant concentrations below the
limit of quantification.
The analysis of the silver corrosion layer proved that it is mainly composed of silver
chloride (AgCl). We were unable to establish a direct relationship between the nature of
the corrosion layer and the pollutants monitored, since the AgCl is likely due to the
presence of marine aerosols inside the NMAA. |